{"product_id":"cleerline-ssf-tkite-100-clr-tkite-100-basic-fiber-optic-testing-kit","title":"Cleerline SSF-TKITE-100 \/ CLR-TKITE-100 Basic Fiber Optic Testing Kit with Case","description":"\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e New\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Cleerline\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN:\u003c\/strong\u003e SSF-TKITE-100\u003c\/p\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003eManufacturer:  \u003cstrong\u003eCleerline\u003c\/strong\u003e\n\u003c\/div\u003e\u003cdiv\u003eModel:  \u003cstrong\u003eSSF-TKITE-100\u003c\/strong\u003e\n\u003c\/div\u003e\u003cdiv\u003eDescription:  Fiber Testing Kit\u003c\/div\u003e\u003cdiv\u003eCondition:  \u003cstrong\u003eNew\u003c\/strong\u003e in Sealed Box\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cstrong\u003eOverview\/Description\u003c\/strong\u003e (from manufacturer's website)\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003eThe SSF-TKITE-100 Basic Fiber Testing Kit provides basic optical link testing and qualification for single-mode and \u003c\/div\u003e\n\u003cdiv\u003emultimode fibers.  The included Optical Power Meter and Optical Light Source units comprise a simple solution for \u003c\/div\u003e\n\u003cdiv\u003etroubleshooting installed fiber.  This kit can be used to calculate general optical power loss in decibels (dB).  It is not \u003c\/div\u003e\n\u003cdiv\u003eintended for network certification to TIA-568-C standards, but provides an easy-to-operate qualification solution.  \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eThe test kit tests on four wavelengths (850, 1300, 1310, and 1550 nm) with a range of 70 dB. The conveniently smallsized testing units include one single-mode light source, \\one multimode light source, and a power meter. All testing units have a backlit LCD display and include an auto shut-off function for extended battery life. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eAdapters for both SC and LC terminated cables are included in the kit, along with a full pack of reference cables. All materials are contained in a rugged case that keeps the items within neat, organized, and protected. \u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003eChoose the SSF-TKITE-100 as a simple solution for quick, general qualification and troubleshooting of installed fiber.\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eFeatures \u0026amp; Benefits\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003e• Test kit includes carrying case \u003c\/div\u003e\n\u003cdiv\u003e• Tests both multimode and single-mode fibers\u003c\/div\u003e\n\u003cdiv\u003e• Wavelengths of 850, 1300, 1310, and 1550nm\u003c\/div\u003e\n\u003cdiv\u003e• SC ports and LC type MM and SM adapters\u003c\/div\u003e\n\u003cdiv\u003e• SC and LC reference cables included \u003c\/div\u003e\n\u003cdiv\u003e• Auto shut-off function for extended battery life\u003c\/div\u003e\n\u003cdiv\u003e• Up to 100hr battery run time (3 AAA batteries - not included)\u003c\/div\u003e\n\u003cdiv\u003e• Easy reference power setup\u003c\/div\u003e\n\u003cdiv\u003e• Convenient LCD display\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eKit Contents (Included)\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\n\u003cdiv\u003e1 Power Meter\u003c\/div\u003e\n\u003cdiv\u003e1 Light Source (Multi-mode): 850 nm, 1300 nm\u003c\/div\u003e\n\u003cdiv\u003e1 Light Source (Single-mode): 1310 nm, 1510 nm \u003c\/div\u003e\n\u003cdiv\u003e1 REFCBL-TKITE100 (MM \u0026amp; SM Reference Patch Cables)\u003c\/div\u003e\n\u003cdiv\u003e2 SSF-SCLC-MMADP (SC Male to LC Female MM ADP)\u003c\/div\u003e\n\u003cdiv\u003e2 SSF-SCLC-SMADP (SC Male to LC Female SM ADP)\u003c\/div\u003e\n\u003cdiv\u003e1 SSF-SSCSC-MMADP (SC-SC Female MM ADP)\u003c\/div\u003e\n\u003cdiv\u003e1 SSF-SSCSC-SMADP (SC-SC Female SM ADP)\u003c\/div\u003e\n\u003cdiv\u003e1 SSF-SLCLC-MMADP (LC-LC Female MM ADP)\u003c\/div\u003e\n\u003cdiv\u003e1 SSF-SLCLC-SMADP (LC-LC Female SM ADP)\u003c\/div\u003e\n\u003cdiv\u003e1 Carrying Case\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/div\u003e\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\u003cdiv\u003eStandard shipping anywhere in the contiguous United States is \u003cstrong\u003eFREE\u003c\/strong\u003e!\u003c\/div\u003e","brand":"Cleerline","offers":[{"title":"Default Title","offer_id":45687475699781,"sku":"26C-DJP","price":379.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1454\/7130\/files\/57_2c272028-1dce-41c7-b410-57da5a10a7ca.jpg?v=1788465920","url":"https:\/\/lpav.com\/products\/cleerline-ssf-tkite-100-clr-tkite-100-basic-fiber-optic-testing-kit","provider":"LPAV","version":"1.0","type":"link"}